Title: Banco de pruebas para electrobombas de bajas potencias 1/4HP A 1HP
Authors: Arias Mesa, Diana Marcela
metadata.dc.contributor.advisor: Villa Salazar, Arley Fernando
Lemmel Vélez, Karen
metadata.dc.subject.proposal: Electrobombas
Hidráulica
Instrumentación industrial
Instrumentos de control
Máquinas eléctricas
metadata.dc.subject.keyword: Electric pumps
Hydraulics
Publisher: Institución Universitaria Pascual Bravo
Abstract: Este documento describe el diseño y la construcción de un banco de pruebas para medir el rendimiento de electrobombas de baja potencia (1/4HP a 1HP). La función del banco es graficar la curva característica de esta bomba. Una curva característica es la relación entre el caudal y la altura de descarga, graficada para diferentes puntos de operación. Inicialmente se definieron los materiales, componentes y características de todas las partes de la parte hidráulicas. Luego se continuo con la selección de los elementos de medición de variables e instrumentos para la adquisición de los datos. Finalmente se logró con éxito realizar el banco de pruebas, se graficó curva de las electrobombas de bajas potencias. Se obtuvieron resultados confiables para las variables medidas y se demostró la capacidad del banco de pruebas para caracterizar el comportamiento de las bombas en distintas condiciones de operación.
metadata.dc.description.abstracteng: This paper describes the design and construction of a test bench to measure the performance of low power (1/4HP to 1HP) electric pumps. The function of the bench is to plot the characteristic curve of this pump. A characteristic curve is the relationship between flow rate and discharge head, plotted for different operating points. Initially, the materials, components and characteristics of all the parts of the hydraulic part were defined. Then we continued with the selection of the variable measurement elements and instruments for data acquisition. Finally, the test bench was successfully carried out and the curve of the low power electric pumps was plotted. Reliable results were obtained for the variables measured and the capacity of the test bench to characterize the behavior of the pumps under different operating conditions was demonstrated.
URI: https://repositorio.pascualbravo.edu.co/handle/pascualbravo/2550
Appears in Collections:Tecnología en Sistemas Electromecánicos

Files in This Item:
File Description SizeFormat 
Rep_IUPB_Tec_Sis_Elec_Meca_Electrobombas.pdf3,67 MBAdobe PDFView/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons